Chapter 6: Data Details Tables
DE5450S Remote Programmer Guide Rev. 8 33
6.6 PGM
PowerMax/PowerMaster control panels can open or close the programmable
(PGM) output as a result of a certain event or condition. This table enables you to
determine the events and conditions under which the PGM (programmable)
outputs will function.
Note: In some versions of the PowerMax+ and PowerG, the PGM will also include
a scheduler, (see 6.15 X-10 Device Settings for further details). When the X-10
device settings table is uploaded, the Remote Programmer will also load the PGM
table. However, this does not occur the other way around.
6.7 Internal Siren/Strobe
This defines the operation of the INT output in the control panel.
Internal Siren - enables you to activate the output for a certain amount of (Bell)
time. Strobe - activates the output until the system is disarmed.
6.8 X-10 General Features
This screen enables you to set the general features for the X-10 units. The House
Code must be a letter between A and P that distinguishes this particular PowerMax
X-10 unit from others.