User Manual, Version 1.0 11
CHAPTER 3
In This Chapter
Initial Connection and Setup .......................................................................... 11
Retrieving or Setting Network Parameters through a USB Thumb Drive ............... 13
Initial Connection and Setup
The MGW Ace Decoder is configured, by default, to use a fixed static IP address for its
streaming and management port (labeled "Ethernet1"). Use the default 192.168.1.2 IP
address to perform initial login from a computer connected directly to the platform.
To configure the appliance's network settings for the first time:
1. Connect a power source to the rear power input port.
2. Connect the network port labeled "Ethernet1" to a computer with network IP
configured to 192.168.1.x range with subnet 255.255.255.0 and ensure you can ping
the default IP address of the unit to 192.168.1.2.
3. Open a web browser and type the appliance's IP address in the URL field. The login
window appears.
4. Type the password (the default password is "1qaz!QAZ") and click the blue arrow. The
MGW Ace Decoder interface is loaded.