VIVOTEK
184 - User's Manual
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
baudrate 110,300,600,120
0,2400,3600,480
0,7200,9600,192
00,38400,57600,
115200
9600 4/4 Set baud rate of COM port.
databit 5,6,7,8 8 4/4 Data bits in a character frame.
paritybit none,
odd,
even
none 4/4 For error checking.
stopbit 1,2 1 4/4 1
2-1.5 , data bit is 5
2-2
uartmode rs485,
rs232
rs485 4/4 RS485 or RS232.
customdrvcmd_i<0~
9>
string[128] <blank> 1/4 PTZ command for custom camera.
speedlink_i<0~4>_n
ame
string[40] <blank> 1/4 Additional PTZ command name.
speedlink_i<0~4>_c
md
string[40] <blank> 1/4 Additional PTZ command list.
ptzdriver 0~19,
127 (custom),
128 (no driver)
128
(no driver)
1/4 The PTZ driver is used by this COM
port.