EasyManua.ls Logo

Vivotek FE8172 - Page 192

Vivotek FE8172
219 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIVOTEK
192 - User's Manual
\r\n
do1=1\r\n
8.4 3D Privacy Mask
Note: This request requires admin user privilege
<SD81X1> You can set privacy mask only at zoom 1x. To go back to zoom 1x directly, please send this
cgi command: "/cgi-bin/camctrl/camposition.cgi?setzoom=0"
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/admin/setpm3d.cgi?method=<value>&name=<value>&[maskheight=<val
ue>&maskwidth=<value>&return=<return page>]
PARAMETER VALUE DESCRIPTION
method add Add a 3D privacy mask at current location
delete Delete a 3D privacy mask
edit Edit a 3D privacy mask
maskname string[40] 3D privacy mask name
maskheight integer 3D privacy mask height
maskwidth integer 3D privacy mask width
return <return page> Redirect to page <return page> after the 3D privacy mask is
configured. The <return page> can be a full URL path or
relative path according to the current path. If you omit this
parameter, it will redirect to an empty page.

Table of Contents