7.39 Seamless recording setting
Group: seamlessrecording (capability.localstorage.seamless > 0)
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
diskmode seamless,
manageable
seamless 1/6 “seamless” indicates enable seamless
recording.
“manageable” indicates disable seamless
recording.
maxconnection 3 3 1/6 Maximum number of connected
seamless streaming.
stream 1~4 1 7/7 (Internal used, read only)
output 0~2 2 7/7 (Internal used, read only)
enable <boolean> 0 1/6 Indicate whether seamless recording is
recording to local storage or not at
present.
(Read only)
guid<0~2>_id string[127] <blank> 1/6 The connected seamless streaming ID.
(Read only)
guid<0~2>_number 0~3 0 1/6 Number of connected seamless
streaming with guid<0~2>_id.
(Read only)
7.40 genetec info
Group: genetec
NAME VALUE DEFAULT SECURITY
(get/set)
DESCRIPTION
image_contrast <integer> <product
dependent>
7/7 Only for genetec omnicast
image_brightness <integer> <product
dependent>
7/7 Only for genetec omnicast
motion_i<0~4> <integer> <product
dependent>
7/7 Only for genetec omnicast