Exposure
On this page, you can congure the Exposure measurement window, Exposure level, Exposure mode,
Exposure time, and Gain control settings. You can configure two sets of Exposure settings: one for
normal situations, the other for special situations, such as the day/night/schedule mode.
Measurement Window: This function allows users to set measurement window(s) for low light
compensation. For example, where low-light objects are posed against an extremely bright background.
You may want to exclude the bright sunlight shining through a building's corridor.
■ Full view: Calculate the full range of view and offer appropriate
light compensation.
Custom: This option allows you to manually add customized windows as inclusive or exclusive regions.
A total of 10 windows can be congured. Please refer to the next page for detailed illustration.
Sensor Setting 1:
For normal situations
Sensor Setting 2:
For special situations