Example: request IP address and it’s response
Request:
http://192.168.0.123/cgi-bin/admin/getparam.cgi?network_ipaddress
Response:
HTTP/1.0 200 OK\r\n
Content-Type: text/html\r\n
Context-Length: 33\r\n
\r\n
network.ipaddress=192.168.0.123\r\n
Set server parameter values
Note: This request require administrator access
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/admin/setparam.cgi?
[nosync=<value>&]<parameter>=<value>
[&<parameter>=<value>…][&return=<return page>]
parameter value description
<group>_<name>.
value to assigned
Assign <value>
to the parameter
<group>_<name>..
return
<return page> Redirect to the page <return page> after the
parameter is assigned. The <return page> can be a
full URL path or relative path according the the current
path. If you omit this parameter, it will redirect to an
empty page.