196 - User's Manual
7.36 Object tracking setting
Group: sdobjtrack.
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
objsize_type -1~2 -1 1/4 Type of object size.
-1 : customized width and height
0 : object size = 30 x 30
1 : object size = 10 x 20
2 : object size = 10 x 10
objsize_customized_widt
h
10~320 30 1/4 The minimum width of tracking target.
objsize_customized_heig
ht
10~240 30 1/4 The minimum heght of tracking target.
sensitivity 0~2 1 1/4 Tracking sensitivity.
0 : Low
1 : Medium
2 : High
7.37 Seamless recording setting
Group: seamlessrecording (capability.localstorage.seamless > 0)
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
diskmode seamless,
manageable
seamless 1/6 “seamless” indicates enable seamless
recording.
“manageable” indicates disable seamless
recording.
maxconnection 3 3 1/6 Maximum number of connected
seamless streaming.
stream 1~4 1 1/6 (Internal used, read only)
output 0~3 2 1/6 (Internal used, read only)
enable <boolean> 0 1/6 Indicate whether seamless recording is
recording to local storage or not at
present.
(Read only)
guid<0~2>_id string[127] <blank> 1/6 The connected seamless streaming ID.