20 21
SANITIZING AND FILTER CHANGE
Make sure Do Not Use sign is
displayed throughout the entire sanitation
process.
Always wear safety glasses
while handling the sanitizing chemicals.
Turn the main Water Supply OFF and place the
Cleaning Switch in the OFF position.
BOOST
PUMP
ON
OFF
FUSE
T10A
Cleaning
Switch
Cleaning Switch to OFF Position
To drain down both Still and Sparkling Water, press
the Blue and Green Buttons on the Dispensing
Head until the water stops.
Press to Drain Still and Sparkling Water
Conrm the proper CO
2
Pressure 65-70 PSI at the
Regulator and adjust if necessary.
Regulator
CO2 Cylinder
CO
2 Pressure
65–70 PSI
Conrm CO
2
Pressure
Remove the old Filter Cartridge by turning counter-
clockwise and pulling down.
Remove Old Water Filter
Using the supplied Syringe, ll Sanitizing Cartridge
with 2ml (about 1/2 teaspoon) of Sanitizing Solution
and insert Sanitizing Cartridge into Dispensing
Head.
Sanitizing
Solution
Sanitizing
Cartridge
2 ml
Insert Sanitizing Solution
Turn the water supply back ON.
If working on a Vivreau ViTAP Dispensing System
with a Boiler, turn the handle on the Filter Head to
BYPASS the Dispensing Head during sanitation.
Turn Handle to BYPASS
Press and Hold the Blue Still Water Button and
dispense water just until the Sanitizing Solution
appears, then release the button.
Sanitizing
Solution
Press and Hold Until Sanitizing Solution Appears
Place the Cleaning Switch in the ON position and
let the Carbonator cycle.
BOOST
PUMP
ON
OFF
FUSE
T10A
Cleaning
Switch
Cleaning Mode Switch to ON Position
Place the Cleaning Switch in the OFF position.
BOOST
PUMP
ON
OFF
FUSE
T10A
Cleaning
Switch
Cleaning Switch to OFF Position
Press and Hold the Sparkling Water Button
until Sanitizing Solution is dispensed. Leave
Sanitizing Solution in the lines for at least
10 minutes.
Check all ttings and connections for leaks.
Clean and wipe the entire system with a soft
cloth using anti-bacterial spray; you can also use
disposable sanitizing wipes. Pay close attention to
the Drip Tray and inside the Drip Tray; remove any
scale deposits found.
Clean Condenser Grille with a soft brush and
remove any dust or grease.
When the sanitizing time has elapsed, turn the
Water Supply OFF and drain the Still Water from
the Dispensing Head until the water stops.
Remove Sanitizing Cartridge and install a new
Filter.
Turn Water Supply ON and dispense at least ve (5)
gallons of Still Water or until the water is clear and free
of any Sanitizing Solution.
Press and Hold the Green Sparkling Button
and ush until water stops and only CO
2
gas is
dispensed.
Place the Cleaning Switch in the ON position and
allow the Carbonator to completely ll before
turning it back off again.
Press and Hold the Green Sparkling Button again
until just CO
2
gas is dispensed. Repeat this process
at least four (4) times to ensure all of the Sanitizing
Solution has been ushed out.
If working on a Vivreau ViTAP Dispensing System
with a Boiler, remove the old Boiler Filter and replace
with the new one.