10. TROUBLESHOOTING
10.1. How to resolve possible problems
[B]= battery machines
[C]= cable machines
[BT]= battery machines with electric drive
Possible problems affecting the whole machine.
PROBLEM
CAUSE
REMEDY
The machine does not work
[B]= battery connector
disconnected
[B]= connect the batteries to
the machine
• [B]= the batteries are flat • [B]= recharge the batteries
The brushes do not turn
[B], [BT]=
you have not used
the brush switch
• press the brush switch
you have not pressed the brush
lever
• press the brush lever
[B]= the motor thermal cutout
has tripped; the motor is
overheated
[B]= release the brush lever;
leave the machine to cool
down for at least 45'
[B], [BT]=
the power supply or
motor thermal cutout connectors
are disconnected
[B], [BT]= reconnect the
power supply or motor
thermal cutout connectors
[B] [BT]=
the brush motor
fuse has blown
[B] [BT]=
have someone
check and eliminate the
causes responsible for the
blown fuse, then replace
• [B] [BT]= the batteries are flat [B] [BT]= recharge the
batteries
• the reduction unit is faulty have the reduction unit
replaced
• the motor is faulty • have the motor replaced
The machine does not clean
evenly
• the brush or disks are worn • replace