SERVICE LOG
Clears service messages, and records the last ten system service
times.
If the display has been showing a reminder for the 500 hour service,
once the service has been completed, you can enter this section and
clear the message. This also records the system hours when the
service was completed. The display will show:
500HR CLEAR?
Push and hold the ON button for 5 seconds, it will be cleared. Scroll
through each recorded service with the ON and OFF buttons.
AIR TEMP. SENSOR
Allows temporary over-ride of the compressor temperature sensor.
This is only intended for use in an emergency to
complete a job when servicing the unit is not
immediately possible. Running without a temperature
sensor may result in failure of the unit and/or damage to
the hydraulic system, and is not recommended.
To temporarily disable the temperature sensor, press and hold the
ON button for 2 seconds. The display will show:
NO AIR TEMP PRB?
Press and hold the ON button for 5 seconds. The display will show:
TEMP PROBE DIS
The air temperature sensor has been disabled.
If you press and hold the OFF button for 5 seconds, the display will
show:
TEMP PROBE EN
The air temperature sensor has been enabled.