RESTART PRESSURE
Allows adjustment of the system restart pressure.
Range: 80 to 120 PSI (limited to 30psi or more below the UNLOAD
PRESSURE). Factory Setting: 120 psi
Press and hold the ON button for 2 seconds. The display will show:
ADJ ON PRES XXX
The XXX is the current pressure setting in psi. Scroll through the
range of settings. When the desired setting is displayed, exit
normally, and the change will be made.
DELAY TO STANDBY
Allows adjustment of the time delay before the system goes to
STANDBY mode and turns off the compressor.
Range: 30sec, 45sec, 1, 2, 5, 10, 15, 30 min and Never.
Factory Setting: 2 min.
Scroll through the range of settings using the ON and OFF buttons.
When the desired setting is displayed, exit normally, and the change
will be made.
COLD START LOG
A record of the last ten cold-start temperatures below 32F(0 C).
This information can be recorded on the VMAC troubleshooting form
and faxed to VMAC to assist in troubleshooting issues.
Scroll through each logged cold-start temperature using the ON and
OFF buttons.