Transportation, Storage and Handling
4.3.2 After Storage
Remove the temporary protections and visually check the condition of all the elements.
If the pump has been stored and/or stopped for a long period of time (more than 6 months) it is necessary:
o Renew the lubrication of bearings.
o Check the condition of the gaskets.
o Check leveling.
o Check all auxiliary connections.
After a short storage period, it is sufficient to manually rotate the pump shaft to unlock the rotor assembly.
Carry out the instructions for after short storage specific to the manuals of motors and other elements.
Observe the other steps listed in the "Start-up" section.
If the equipment is going to be stopped for a certain period of time and there is danger of frost, it is necessary to drain the
pump completely to avoid its deterioration due to the possible freezing of the contained fluid.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vogt MD Series and is the answer not in the manual?

Vogt MD Series Specifications

General IconGeneral
TypeMulti-Stage Centrifugal Pump
PowerElectric
MaterialsCast Iron, 316 Stainless Steel
MaterialCast Iron / 316 Stainless Steel
Inlet SizeDN32 to DN100
Outlet SizeDN 25 to DN 80
CapacityUp to 200 m³/h
HeadUp to 300 m
Operating Temperature-10°C to +120°C

Related product manuals