Maintenance
Maintenance
7.7 Stamp with Estopa Press
There are two executions of stuffing box sealing, the standard execution, for clean fluids, see figure 22 and the special
execution with lantern ring for dirty fluids, this execution needs external lubrication with clean and fresh fluid, see figure 23.
For more details of operation and maintenance of the gland sealing system refer to the annex SERVICE AND MAINTENANCE
Gland Sealing. However, in general, when a new pump is operated for the first time or the packing has been renewed, the
operation of the packing should be carefully observed periodically. During the first hours of operation the packing press may
leak quite a lot, approximately 100 drops per minute. Later in normal operation, a leakage of only 5 to 30 drops per minute
should be maintained. When selecting the type of packing, observe the quality, the temperature of the liquid to be pumped and
the material of the pump shaft.
Description :
1.- Packing
2.- Cable Gland Bushing
3.- Cable Gland Flange
4.- Cable Gland Adjusting Nut
5.- Diffuser Ring or Lantern Ring
6.- External Lubrication and Coolant Connection Nipple
Figure 22
Standard Execution Special Execution
(Lantern Ring)
Figure 23
1
2
3
4
5 6
1
2 3
4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vogt MD Series and is the answer not in the manual?

Vogt MD Series Specifications

General IconGeneral
TypeMulti-Stage Centrifugal Pump
PowerElectric
MaterialsCast Iron, 316 Stainless Steel
MaterialCast Iron / 316 Stainless Steel
Inlet SizeDN32 to DN100
Outlet SizeDN 25 to DN 80
CapacityUp to 200 m³/h
HeadUp to 300 m
Operating Temperature-10°C to +120°C

Related product manuals