EasyManua.ls Logo

VOLTCRAFT VC-530 - Technical Data

VOLTCRAFT VC-530
104 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
Display 6000 counts
Measuring frequency approx. 2 measuring operations/second
Measuring impedance >10MΩ (V range)
Operating voltage 9 V block battery
Working conditions 5°C to 40°C; max. 80% RH
Operating altitude max. 2,000 m
Storage conditions -20°C to +60°C; max. 80% RH
Weight ca. 271 g
Dimensions (LxWxH) 232 x 77 x 39 (mm)
Opening width current sensor 40 mm
Over-voltage category CAT III 600 V
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of
smallest points)). The accuracy is valid for one year at a temperature of +23°C ±
5°C, and at a relative humidity of less than 75 %, non-condensing.
Alternating current (AC/A)
Range 50-60 Hz Accuracy Definition
600.0 A ±(3,5 % + 10) 100 mA
1000 A ±(3,8 % + 10) 1 A
Range 60-400 Hz Accuracy Definition
600.0 A ±(6 % + 12) 100 mA
1000 A ±(7 % + 12) 1 A
Direct current (DC/A) VC-531 only
Range Accuracy Definition
600.0 A ±(3,5 % + 10) 100 mA
1000 A ±(3,8 % + 10) 1 A
50