Impeller, Check and Change
WARNING!
Risk of water entry. Close the seawater cocks before
doing any work on the seawater system.
1 Close the sea cock.
2 Remove cover on the seawa-ter pump. Remove
impeller .
If there are cracks or other defects the impeller must
be replaced.
3 Lubri-cate the pump housing and the inside of the
cover with a little glycerin.
IMPORTANT!
Impellern skadas om andra typer av smörjmedel än
glycerin används.
4 Reinstall the impeller using a clockwise rotating
movement.
5 Install the cover together with a new gasket. Open
the sea cock.
Always carry a spare impeller on board.
Maintenance
47702088 05-2011 49
47702088 - Downloaded from www.volvopenta.com 02/06/2011 18:54:55