Emergency Stop Switch
Reset auxiliary stop button.
Battery Voltage
Check belt tension. Refer to Drive Belt, Check and Change page 76.
Check battery fluid level. Refer to Battery, Maintenance page 97.
Check Corrosion Status
The active corrosion protection (ACP) status is unknown. Corrosion protec-
tion not guaranteed. Refer to Optional page 46.
The active corrosion protection (ACP) is not available. Check that the bat-
teries are charged by land current or by the alternator.
Check Control Lever
Shift and throttle incorrect.
Slip function not available.
Acknowledge fault by moving control to neutral and press OK-button.
Engine power is reduced. Gear automatically set to neutral.
Check Engine
Miscellaneous system faults. Engine performance might be affected.
Some possible explanations to the disturbance listed.
• Battery voltage incorrect.
Check belt tension. Refer to Drive Belt, Check and
Change page 76.
Check battery fluid level. Refer to Battery, Maintenance page 97.
•
Fuel pressure incorrect. Engine performance might be affected.
• Communication failure. Gear automatically set to neutral. Engine per-
formance might be affected.
• Oil pressure too low.
Engine power is reduced. Checking Engine Oil Level. Refer to Oil level,
checking and topping up page 78.
Check that no leakage occurs.
Please contact a Volvo Penta workshop if the fault remains.
Check EVC System
Internal fault in EVC system. Engine performance might be affected.
Some possible explanations to the disturbance listed.
• Limited or no steering. Please contact a Volvo Penta workshop.
• Shift and throttle unavailale. Gear automatically set to neutral. Engine
power is reduced. Helm station has lost communication with engine.
Use alternative helm station if possible.
• Control panel failure. Check if any button has stuck.
Please contact a Volvo Penta workshop if the fault remains.
Check Multilink
Limited instrumentation. Control unit has communication fault.
Fault Code Register
47702095 04-2011 63