- 8 -
6.2OtherMalfunctionsandSolutions(NodisplayonLEDwirecontroller)
Malfunctions Observing Reason Solution
Heatpumpis
notrunning
LEDwirecontroller
nodisplay.
Nopowersupply.
Checkcableandcircuitbreakerif
itisconnected.
LEDwirecontroller
displaystheactual
watertemperature.
1.Watertemperatureis
reachingtosettingvalue,HP
underconstanttemperature
status.
2.Heatpumpjuststartstorun.
1.Verifywatertemperature
setting.
2.Startupheatpumpafterafew
minutes.
Shortrunning
LEDdisplaysactual
watertemperature,no
errorcodedisplays.
1.FanNOrunning.
2.Airventilationisnotenough.
1.Checkthecableconnections
betweenthemotorandfan, if
necessary,itshouldbereplaced.
2.Checkthelocationofheat
pumpunitandeliminateall
obstaclestomake
goodair
ventilation.
Waterstains
Waterstainsonheat
pumpunit.
1.Concreting.
2.Waterleakage.
1.Noaction.
2.Checkthetitaniumheat
exchangercarefullyifitisany
defect.