Commissioning
7.2 Tests before commissioning
Ground conditions
The maximum dumping height depends on several factors of the ground
conditions. An exact specification of this value is not possible.
Determine the maximum fill height by compaction tests or soil
samples.
Shaking in cobblestones
To avoid damage to the machine or compaction material, use a slid-
ing device, see Accessories on page 49.
Compaction of asphalt
To avoid cracking and sticking to the asphalt, use water tank with
sprinkler system, see Accessories on page 49.
7.2 Tests before commissioning
Information
Further information and detailed descriptions, see Mainten-
ance on page 38.
Perform the following checks:
Check machine and components for damage.
Do not put the damaged machine into operation. Damages and
defects must be repaired immediately.
Check the fuel level.
Check fuel lines for leaks.
Check air filter.
Check engine oil fill level.
Check reversing starter.
Check to ensure the screw connections are firmly seated.
Check control elements for functionality.
7.3 Putting into operation with Honda engine
WARNING
Danger of burns due to starting aid sprays!
Starting aid sprays can ignite and cause severe burns.
Do not use any starting aid sprays.
34 Operator’s Manual | BPS1030A, BPS1135A, BPS1340A, BPS1550A, BPS2050A | BPS | 5100060577 | 01/2023 |