Maintenance BPU 2440/2950 Repair
wc_tx000328gb.fm 24
4.5 Cleaning Sediment Cup
See Graphic: wc_gr000029
4.5.1 Turn fuel valve off.
4.5.2 Remove sediment cup (a) and O-ring (b).
4.5.3 Wash both thoroughly in a nonflammable solvent. Dry and reinstall
them.
4.5.4 Turn fuel valve on and check for leaks.