MAINTENANCE
Maintenance schedule
Check all external screw connections for tight fit approx. 8 hours after first operation.
Parts Maintenance jobs Maintenance interval
Air filter Check for external damage and tight fit. daily
Check filter cartridge, clean or replace if
necessary.
Fuel tank Check tank lid fortight fit, replace if
necessary.
Drive engine Check oil level, top up if necessary.
Exciter Check for tightness.
Drive engine First oil change. after 20 hours
Centre pole Grease moveable locking device, and spindle weekly
for pole height adjustment.
Drive engine Clean spark plug, check spark plug gap monthly
0,7 mm.
Centre pole head Check oil level, top up if necessary.
V-belt Check V-belt tension-retension, if
need be.
Protective frame Check fastening screws of protective frame and
central suspension for tight fit.
Fuel tank Check fuel filter for flow, repalce if after 100 hours
necessary.
Exhaust muffler Remove combustion residue from spark arrester.
Drive engine Further oil changes.
Exciter Check oil level-fill up, if need be. after 150 hours
Exciter Oil change. after 250 hours
Drive engine Valve clearance - Check, set - 0,15 mm after 300 hours
intake valve, 0,20 mm exhaust valve.

Other manuals for Wacker Neuson BPU 2950A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson BPU 2950A and is the answer not in the manual?

Wacker Neuson BPU 2950A Specifications

General IconGeneral
BrandWacker Neuson
ModelBPU 2950A
CategoryPower Tool
LanguageEnglish

Related product manuals