MAINTENANCE
Maintenance schedule
Check all external screw connections for tight fit approx. 8 hours after first operation.
Parts Maintenance jobs Maintenance interv.
Air filter Oil bath air filter - Check oil pan for oil level and dirt. daily
Clean or top up if necessary.
Dry-type air filter - see visual maintenance display,
clean or replace filter cartridge if necessary.
Engine Check oil level, top up if necessary.
Check crank and crank carrier for correct fastening.
Exciter Check for tightness.
Engine First oil change. after 25 hours
Other parts Grease moveable locking device, and spindle for pole weekly
height adjustment.
Tow-bar head Check oil level, top up if necessary. monthly
V-belt Check V-belt tension - retension, if need be.
Other parts Check fastening screws of protective frame and
central suspension for tight fit.
Engine Further oil changes. after 150 hours
Checking coolings fins for dirt-clean dry if necessary.
Tighten all accessible screw connections.
Exciter Oil change.
Valve clearance Check, set to 0,1 mm when motor is cold. after 300 hours
Injection nozzle Function check 200 bars.