16
MAINTENANCE
Maintenance schedule
Component Maintenance work Maintenance interval
External hardware Check for tightness. approx. 8 hours after
initial start-up
Drive engine First oil change and filter. 25 hours after initial
Valve clearance Cold engine: Check valve clearance, and adjust start-up
if necessary.
Inlet valve 0,1 mm - outlet valve 0,2 mm.
Air filter Check dry type air filter - clean or replace filter daily
cartridge if necessary (pay attention to the
maintenance indication).
Drive engine Check oil level, if nec. top up oil.
Centre pole height Regrease. weekly
setting, transport
lock
V-belt Check V-belt, if. nec. replace. monthly
Protective frame, Check attachment screws for tight fit.
central lifting point
Tow-bar head Check oil level, top up if necessary.
Drive engine Oil change, change oil filter. every 250 h
Keep cooling fins free of dirt, clean dry.
Retighten all accessible screw connections.
Exciter Oil change.
Battery Check acid level, if nec. top up with distilled water.
Valve clearance Cold engine: Check valve clearance, and adjust
if necessary.
Inlet valve 0,1 mm - outlet valve 0,2 mm.
Fuel filter Change filter. every 500 h

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson DPU 5045H and is the answer not in the manual?