Maintenance G 50/G 70/G 85
wc_tx000484gb.fm 48
4.2 New Machines
4.2.1 Run generator at least 60–100% of continuous load for the first 100
hours.
4.2.2 Change engine oil and replace oil filter after the first 50 hours.
4.3 Resetting the Periodic Maintenance Timer
After maintenance has been performed on the generator, it is
necessary to reset the periodic maintenance timer.
If the periodic maintenance timer is at zero, press the ENG. HRS
switch UP and hold for 10 seconds until the “TIME TO SERVICE”
resets to 250 hours.
If the service time is greater than zero (maintenance was performed
prior to the timer running out) press and hold the ENG. HRS switch UP
and hold for 30 seconds. This will reset the “TIME TO SERVICE” to
250 hours.