57
PXM
OPERATING AND ASSEMBLY MANUAL
VERSION 08/2015 ORDER NUMBER DOC2350372
Home page
Cleaning
Settings
Alarm
Work-
station
FP
supply
Exhaust
system
Diagnosis
FP station
Settings System
No
RP
supply
Standard
No
FP bigbag
FP redosing time man. [sec]
FP redosing time auto [sec]
Parameter: Explanation:
FP station No: No fresh powder pump available
1: A fresh powder pump is available (installed)
2: Two fresh powder pumps are available (installed)
FP Bigbag No: No fresh powder pump available on the bigbag
1: An external fresh powder pump is available (installed)
2: Two external fresh powder pumps are available (installed)
Bigbag type
FP redosing time man. [sec] Redosing time of the fresh powder pump in manual mode
FP redosing time auto [sec] Redosing time of the fresh powder pump in automatic mode
If the "FP bigbag" parameter is set to 1 or 2, then the "Bigbag type" parameter is displayed.
Bigbag type
MP
operation
MP
cleaning