76
PXM
OPERATING AND ASSEMBLY MANUAL
VERSION 08/2015 ORDER NUMBER DOC2350372
Without Communication with the Application Controller:
PXM: Pressing the "OK" button is used directly as the start command
for the sequence of cleaning steps. No query is made on
whether or not the pulses should begin.
Application: The application controller must be prepared before the start
of the cleaning step:
Bring the guns to the internal cleaning position
(reciprocators and sliding tables)
Switch on reverse air for injectors via dosing and feed air
Example, Pro Tech M:
PXM: Injector cleaning (pulses)
1. An injector series is  ushed rst and subsequently the other
injector series.
Pre- ushing can be set (gentler with short pulses).
Application: Subsequently, if necessary, when controlling the application:
Switch o reverse air for injectors via dosing and feed air
Example, Pro Tech M:
3. Move guns to inside cleaning position (rear)
Guns On
3. Clean the powder center, guns and fesh powder
system
Guns O