8
FORCE TEN
TM
FORCE GAGE
TABLE 3 FORCE TEN -
TECHNICAL
SPECIFICATIONS
Item
Specification
Accuracy
±0.3 % Full Scale (FS) ± 1 Least Significant Digit (LSD)
Display
4-digit, 0.7” Liquid Crystal Display (LCD)
Display Update
8 per
second
Resolution
1000
graduations
(1250
for
25 lbf
capacity)
Tare
20% of Full
Scale (FS)
Overload Protection
15 / 37.5 / 75 / 130 lbf
Power
• 110 or 220 VAC Adapter/Charger
• USB connection
• Rechargeable AAA NIMH battery
Battery Endurance
Up to 20 hours with backlight on
Up to 30 hours with backlight off
Battery Charge
Overnight for full charge
Calibration
Auto-Calibration One full capacity weight
Peak Force Sampling Rate
1200 Samples per second
Menu Selection
Menu selection of:
Unit set lbf, kgf, N, ozf
AoFF set power off time
PSS display sample rate
bLit set backlight off time
tonE set audible button press tone
USB Display baud rate, stop bit, parity
LCAL start auto-calibration
FDX / FPX
SPECIFICATIONS