3.1 EXPLOSION PROTECTION IDENTIFICATION
3.2 IDENTIFICATION X
As de ned in the Directive 94/9/EC (ATEX 95), the device is suitable for use in areas where
there is an explosion hazard.
European Communities
Symbol for explosion protection
Device class II
Category 2 (Zone 1)
Ex-atmosphere gas
Explosion group
Constructional security
Temperature class: maximum surface temperature < 200 °C; 392 °F
Special Notes (see Chapter 3.2)
Maximum surface temperature
The maximum surface temperature of the piston pump can be reached if it runs dry.
Ensure that the piston pump is lled with su cient working or ushing agent.
Ensure that the separating uid container is lled with su cient separating uid.
Ignition temperature of the coating material
Ensure that the ignition temperature of the coating material is above the maximum
surface temperature.
Ambient temperature
The permissible ambient temperature is: +5 °C to +60 °C; +41 °C to 140 °F.
Medium supporting atomizing
To atomize the material, use only weakly oxidizing gases, e.g. air.