4.6 Service System Messages
Display of system information
Display Description Correction
System Messages
All system messages are displayed with a blinking caution symbol.
In case of sensor errors the sensor in question is also marked with short circuit or interruption symbols.
Interruption
Displayed sensor or line connection interrupted
/ defunct.
Check the resistance value of the sensor and
compare to the resistance table.
Check all contact points up to the sensor.
Short circuit
There is a short circuit of the sensor on the
display, the line or the sensor input on the
controller.
dT too high
A fixed value of 20 K is added to the
temperature difference between collector (T1)
and tank sensor (T2). The message is displayed
if after 30 minutes the total temperature
difference has not been reduced.
Check pump/pump connections/wiring.
Check system for air, and vent if required.
Check sensors/sensor lines and change sensor if
required.
4.7 Service Sensor Control
Resistance values for Pt1000-sensors in relation to the temperature
-1C C 1C 2C 3C 4C 5C 6C 7C 8C 9C 10C 11C
961 1000 1039 1078 1117 1155 1194 1232 1271 1309 1347 1385 1423
The working condition of the sensor can be checked with this table and an Ohm meter.
!