EN-SUNGO-S_BA-0804-1122P200 9
4.4 Manual Operation Menu
Manual operation menu
Menu item Description Range Base value
Off = 0/On = 1
Manual on/off via output A1 (solar circulation pump)
0-1 0
Activation of manual operation lag time in automatic mode 0 - 600 min 0 min
4.5 Special Functions Menu
Within the first minute after switching on the controller, select the “Special Functions“ menu in order to activate it, so that
the individual parameters can be changed.
After leaving it, the menu remains active for one minute. Afterwards the parameters can only be viewed but not changed.
In order to change the functions again, it is necessary to disconnect the controller from the mains again.
Special functions menu
Menu
item
Application Description Range
Base value
0 System choice
0 - 1: Standard single-tank system
0 - 2: Cannot be selected!
0 - 3: SECUSOL system (see SECUSOL instructions for further info)
1or3 1
1
System
Protection
Off = 0/On = 1
Activation of system protection.
Cannot be activated with SECUSOL!
0or1 1
2 System protection start temperature 115 - 200 °C 135 °C
3
Collector Cooling
Off = 0/On = 1
Activation of collector cooling.
Cannot be activated with SECUSOL!
0or1 1
4 Collector cooling start temperature 100 - 150 °C 110 °C
5
Tank Cooling
Off = 0/On = 1
Activation of tank cooling. Only possible with collector cooling.
Cannot be activated with SECUSOL!
0or1 0
6 Switch-off temperature 30 - 90 °C 60 °C
7-10 Menu items 7-10 are not available for the SUNGO S controller
11
Tube collector
function
Off = 0/On = 1
Activation of vacuum tube collector function
0or1 0
12 Run time of solar circulation pump from reaching the switch-on value 1 - 60 s 15 s
13 Switch-on value for temperature increase at sensor T1 (collector) 1.0 - 5.0 K 1.0 K
__
T stop
Only expert personnel
should edit the special functions menu.
Incorrect settings may adversely affect the solar heating
system.