Assembly Instructions Dosing Valves WDV-0x
Page 1 of 34
Walther Systemtechnik GmbH D 76726 Germersheim
Telefon: +49 (0)7274-7022-0 Telefax: +49 (0)7274-7022-91
http://www.walther-2000.de info@walther-2000.de
Assembly Instructions
Dosing Valves
Article Numbers: WDV-01 Dosing volume 0.001 0.020 c
WDV-02 Dosing volume 0.010 0.200 c
WDV-03 Dosing volume 0.100 2.000 c
WDV-04 Dosing volume 1.000 6.000 c
WDV-01
WDV-02
WALTHER-Dosing Valve
0.001 0.020 cm³
(1 20 mm³)
WALTHER-Dosing Valve
0.010 0.200 cm³
(10 200 mm³)
WDV-03
WDV-04
WALTHER-Dosing Valve
0.100 2.000 cm³
(100 2000 mm³)
WALTHER-Dosing Valve
1.000 6.000 cm³
(1000 6000 mm³)
NOTE
Please read these Assembly Instructions carefully before first using the device and strictly
adhere to the instructions!
This device may only be worked with and worked on by persons who are familiar with the
Assembly Instructions and the current regulations for industrial safety and accident
prevention.
Always keep this translation of the “Original Assembly Instructions“ at the device!
The manual has to be available anytime!

Table of Contents

Questions and Answers

  • K
    Kerry Coffey MDAug 11, 2025
    What to do if Walther Systemtechnik WDV-01 sensor gives a permanent signal?
    • P
      Penny BaileyAug 11, 2025
      If the sensor of your Walther Systemtechnik Control Unit is giving a permanent signal, it could be due to several reasons. First, the sensor might be defective and needs replacement. Another cause could be that the dosing volume is too small, requiring you to check the dosing valve, adjust the dosing volume to a higher setting if necessary, and verify the sensor positions. Finally, excessive grease feed pressure could be the problem. In this case, reduce the pump pressure to the dosing valve's maximum operating pressure, and consider using a material pressure regulator.
  • T
    Tina ThompsonAug 17, 2025
    Why is Walther Systemtechnik WDV-01 Control Unit valve actuated, but no lubricant is ejected?
    • D
      Daniel SnyderAug 17, 2025
      If the valve of your Walther Systemtechnik Control Unit is actuated but no lubricant is ejected, it may be caused by the feed pump not feeding lubricant. Check the feed pump and its venting screw, referring to the feed pump's operating manual for guidance. Another possible cause is leakage in the dosing valve, which should be inspected.
  • N
    Nathaniel PhillipsAug 25, 2025
    What to do if Walther Systemtechnik Control Unit sensor has no signal?
    • M
      Micheal AllenAug 25, 2025
      If the Walther Systemtechnik Control Unit sensor has no signal, there are a few potential causes. It could be due to a broken cable, in which case you should replace the cable. Alternatively, the sensor itself might be defective and need replacing. Another possibility is that the dosing piston is in the starting position. To resolve this, check the pump pressure and inspect the grease supply bore hole for any contaminants.
  • J
    jared95Aug 29, 2025
    How to fix air pockets in Walther Systemtechnik WDV-01 grease system?
    • A
      Amy GallegosAug 29, 2025
      To address air pockets in the Walther Systemtechnik Control Unit grease system, which may be due to air in the grease container or tubing, disconnect the tubing to the dosing valve. Drain a quantity of grease and restart the system with the dosage adjustment screw set to maximum.
  • M
    Martin BeckSep 5, 2025
    How to repair leakage at bore hole of Walther Systemtechnik WDV-01 Control Unit?
    • J
      Jennifer ThorntonSep 5, 2025
      If there's leakage at the bore hole of your Walther Systemtechnik Control Unit, it's likely due to defective seals. You should exchange the seals.