EasyManua.ls Logo

Wasp WWS800 User Manual

Wasp WWS800
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
WWS800/850 Bluetooth Wireless Scanners
User’s Manual
© 2008 Wasp Technologies
Table of Contents
Revision History .......................................... Error! Bookmark not defined.
Restore Default Settings ...........................................................................1
Exit Setup without Changes .....................................................................1
Set Connection...........................................................................................1
RF Auto Shutdown Duration ...................................................................1
Transmit Buffer Setting............................................................................1
Memory Mode Parameters.......................................................................2
List Setting.................................................................................................3
Buzzer Settings ..........................................................................................3
Reading Redundancy Setting ...................................................................4
Scan Mode Setting.....................................................................................4
Auto-Sense Setting ....................................................................................4
Scanner Time-out Duration......................................................................5
Negative Barcode Setting..........................................................................5
Delay between Reread ..............................................................................5
Keyboard Wedge Parameters ..................................................................6
RS-232 Parameters....................................................................................9
Bluetooth Serial Port Parameters..........................................................11
Bluetooth HID Parameters.....................................................................12
Prefix / Postfix Settings...........................................................................15
Character Substitution ...........................................................................15
Code ID Selection ....................................................................................15
Code ID Setting .......................................................................................16
Length Code Setting (2 digits)................................................................17
Select Readable Codes ............................................................................20
Code39 Parameters .................................................................................25
Italy Pharmacode Parameters................................................................25
French Pharmacode Parameters............................................................26
Industrial 25 Parameters ........................................................................26
Interleave 25 Parameters........................................................................27
Matrix 25 Parameters.............................................................................29
Codabar Parameters...............................................................................30
Plessey Parameters..................................................................................31
Telepen Parameters.................................................................................31
MSI Parameters ......................................................................................32
EAN128 Parameters................................................................................33
EAN8 Parameters....................................................................................34
UPCA Parameters...................................................................................34
UPCE Parameters ...................................................................................35
EAN13 Parameters..................................................................................36
RSS Code ID Selection............................................................................37

Other manuals for Wasp WWS800

Question and Answer IconNeed help?

Do you have a question about the Wasp WWS800 and is the answer not in the manual?

Wasp WWS800 Specifications

General IconGeneral
Wavelength650 nm
Sensor typePhoto diode
Tilt angle range45 - 90 °
Dimensions (WxDxH)73 x 150 x 91 mm
Compatible operating systemsWindows, NT, DOS & Mac OS
Standard interfacesUSB
Input voltage5 V
CertificationFCC class A, CE, C-tick
Product colorBlack, Yellow
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 50 °C
Weight and Dimensions IconWeight and Dimensions
Weight220 g

Summary

Memory Mode Parameters

Memory Mode

Configures the scanner to operate in memory mode, enabling or disabling it.

Scan Mode Setting

Keyboard Wedge Parameters

RS-232 Parameters

Activate RS232 Interface

Enables or disables the RS-232 serial communication interface.

Baud Rate

Sets the data transmission speed for the RS-232 interface.

Flow Control (single port only)

Manages data flow control for the RS-232 port.

Inter-Character Delay

Sets the delay between transmitted characters over RS-232.

Parity

Configures the parity bit setting for RS-232 communication.

Data Bit

Sets the number of data bits per character for RS-232.

Bluetooth Serial Port Parameters

Activate Bluetooth Serial Port Interface

Enables or disables the Bluetooth serial port connection.

Bluetooth HID Parameters

Activate and Select Keyboard Type

Enables and selects keyboard type for Bluetooth HID connection.

PIN Code

Sets the Personal Identification Number for Bluetooth HID pairing.

Prefix / Postfix Settings

Prefix Code *

Configures a prefix string to be added to scanned data.

Postfix Code *

Configures a postfix string to be added to scanned data.

Code ID Selection

Code ID Setting

Length Code Setting (2 digits)

Code 39 Length Code

Configures length settings for Code 39 barcodes.

Select Readable Codes

Code 39

Enables or disables the scanning of Code 39 barcodes.

Industrial 25

Enables or disables the scanning of Industrial 25 barcodes.

Interleave 25

Enables or disables the scanning of Interleave 25 barcodes.

Matrix 25

Enables or disables the scanning of Matrix 25 barcodes.

Codabar

Enables or disables the scanning of Codabar barcodes.

Code 93

Enables or disables the scanning of Code 93 barcodes.

Code 128

Enables or disables the scanning of Code 128 barcodes.

EAN128

Enables or disables the scanning of EAN128 barcodes.

MSI

Enables or disables the scanning of MSI barcodes.

UPCA

Enables or disables the scanning of UPCA barcodes.

UPCE

Enables or disables the scanning of UPCE barcodes.

EAN8

Enables or disables the scanning of EAN8 barcodes.

EAN13

Enables or disables the scanning of EAN13 barcodes.

RSS14

Enables or disables the scanning of RSS14 barcodes.

RSS Limited

Enables or disables the scanning of RSS Limited barcodes.

RSS Expanded

Enables or disables the scanning of RSS Expanded barcodes.

Code39 Parameters

Industrial 25 Parameters

Interleave 25 Parameters

Matrix 25 Parameters

Codabar Parameters

Plessey Parameters

Telepen Parameters

MSI Parameters

Max / Min Code Length Qualification

Sets maximum and minimum length qualifications for MSI barcode data.

Fixed Code Length Qualification

Sets a fixed length requirement for MSI barcode data.

EAN128 Parameters

EAN8 Parameters

UPCA Parameters

UPCE Parameters

EAN13 Parameters

RSS Code ID Selection

RSS14 Parameters

RSS Limited Parameters

RSS Expanded Parameters

Activate Editing Formats

Editing Format Parameters

Applicable Data Length

Applicable Code Type

Field1 Setting

Field2 Setting

Field3 Setting

Field4 Setting

Field5 Setting

Related product manuals