PREVENTING DAMAGE TO EQUIPMENT
The following recommendations will help avoid damage to your equipment:
Always use the proper fuel mixture.
Do not run the engine at full speed until thoroughly warmed up.
Do not lift strainer out of the water while pump is operating.
Do not run engine with pump disconnected.
Do not run the pump when dry.
Always draft water using a footvalve suction hose strainer.
Check strainer frequently to make sure that it is not clogged with moss, leaves, etc.
Flush the pump with fresh water if the pump has been used to pump salty, brackish,
high mineral content water, water containing debris, or foam injected water. Check that
debris is cleared before using pump again.
Drain pump after final use.
During freezing weather, drain the pump and lines of all water. You can also pour some
antifreeze into the pump and circulate it through the pump and plumbing system.
Pumps should not be operated without water for any extended period of time or without
discharging water. Operating the pump in such a manner can overheat the pump
causing damage to seals, or pump internals.
It is recommended that all fasteners be replaced with genuine WATERAX parts.
INTRODUCTION
About this Manual
This manual contains general operation, care and servicing procedures for the WATERAX
MARK-3 high pressure 4-stage centrifugal pump.
These instructions cover most wildland pump applications. If the application the pump is
being used for does not fall into these general guidelines, consult WATERAX Inc. for any
additional safeguards, operating, or maintenance considerations that may be required.
For full service and maintenance instructions regarding the engine and the pump, please
refer to the Service section.
Please see www.waterax.com additional documentation related to this product such as the
WATERAX product guide, technical notes, news and other updates about WATERAX and
its goods and services.
About the MARK-3
Features
For full specifications and performance curves, see the Product Data Sheet for your pump
end model.
Applications of the WATERAX MARK-3 series include:
Attack line firefighting
Long hose lay for remote watering during firefighting operations
High elevation firefighting in mountainous areas
Accuracy in flow trajectory when structure firefighting
Tandem pumping over long distances
Parallel pumping for higher volumes

Other manuals for Waterax MARK-3