ENG2036-16/01/19
2.3 TECHNICAL INFORMATION
PRODUCT INFORMATION
Features
BioCote® Ye s
UV Technology Firewall™
Dispense area height [mm] 273
Energy saving mode Ye s
Component detail
Refrigerant gas 230V/R600a or 120V/R134a
Refrigerant quantity (g) R600a: 26g; R134a: 65g
TECHNICAL DATA WL7 Firewall™
Working information
Cold water output [°C]* 5
Sparkling water output [°C]* 5
Hot water output [°C]* 75-93
Extra hot water output [°C]* 80-95
Ice Bath capacity [L] 4.5
Sparkling tank capacity [L] 0.5
Hot tank capacity [L] 1.5
Recommended inlet water pressure [bar] 2.5-3.5
Recommended CO
2
pressure [bar] 3
Recommended inlet water temperature [°C] 5-25
Working room temperatures [°C] 2-37
UV Lamp change interval 6 months**
Electrical
Compressor power [W] 110
Pump power [W] 10
Fan power [W] 16
Mixing motor [W] 25
Control power [W] 19
Heating element power [W] 500-800 (model dependent)
UV Lamp [W] 13
Total max power(HCAS) [W] 993
24-hour standby power consumption [kWh] 0.46
Power supply 220-240V/50Hz or 120V/60Hz
Physical
Dimensions (W x D x H) [mm]
399 x 519 x 427
(counter top only)
399 x 519 x 1269
(with base cabinet)
Weight (dry) [kg] 31-34 51-54
** NSF 55 Class A and P231 Certification requirement;
* Performance may vary depending on the local conditions