WL7 FIREWALL
User Manual
Question and Answer IconNeed help?

Do you have a question about the WaterLogic WL7 FIREWALL and is the answer not in the manual?

Summary

General Information

Safety Precautions

Product Certification

Features and Benefits

Front and Rear View

User Interface

Rotating Intuitive Dial

Facilitates easy selection of water options and BioCote protection on the button lens.

Dispense Status Bar

Indicates the current status of water cooling and heating operations.

Bottles Saver Counter

Monitors and displays the number of 500ml plastic bottles saved by using the WL7 FW.

Product Dimensions

Counter Top Dimensions

Specifications including dimensions and weight for the countertop model.

Freestanding Dimensions

Specifications including dimensions and weight for the freestanding model.

Troubleshooting

UV Error

Troubleshooting steps for UV errors, checking UV glow and performing system reset.

Hot Tank Heating Error

Resolving hot tank heating issues by ensuring water supply and resetting the system.

Sparkling Water Level Error

Steps to fix sparkling water level errors, verifying water supply and flow.

Ice Bath Level Error

Troubleshooting ice bath level errors, requiring system reset and supplier contact.

Dispense Time Out

Procedure to reset dispense time out errors and contact supplier if issue persists.

Hot Sensor Error

Resolving hot sensor errors by performing system reset and contacting the supplier.

Ice Detection Error

Troubleshooting ice detection errors, recommending system reset and supplier contact.

Ice Bath Circulation Error

Steps to fix ice bath circulation errors, including system reset and supplier contact.

Overview

The Waterlogic WL7 Firewall™ (WL7 FW) is an advanced water purification system designed for busy workplaces, offering a range of water options and high-tech features in a robust and reliable machine.

Function Description:

The WL7 FW dispenses a large volume of ice-cold and sparkling water, in addition to ambient, hot, and extra-hot water options. It utilizes Waterlogic's patented Firewall™ technology for purification, ensuring 99.9999% purified water at the point of dispense through a highly effective UV antimicrobial system. The machine also incorporates BioCote® antimicrobial protection on key surfaces, which inhibits microbial growth, reduces odors, prevents degradation of surfaces, and minimizes cross-contamination. Best-in-class filtration is provided by Waterlogic filters. The new Ice Bath cooling technology delivers high volumes of consistently cold water, making it suitable for demanding environments. The system is designed for indoor use only and is not intended for treating microbiologically unsafe or contaminated water.

Important Technical Specifications:

  • Water Output Temperatures:
    • Cold water: 5 °C
    • Sparkling water: 5 °C
    • Hot water: 75-93 °C
    • Extra hot water: 80-95 °C
  • Capacities:
    • Ice Bath capacity: 4.5 L
    • Hot tank capacity: 1.5 L
    • Sparkling capacity: 0.5 L - 3 L (model dependent)
  • Dimensions:
    • Countertop: 397 x 519 x 427 mm (31-34 kg)
    • Freestanding: 399 x 519 x 1269 mm (51-54 kg)
  • Dispense Area Height: 273 mm, suitable for filling sport bottles.
  • Recommended Inlet Water Pressure: 2.5-3.5 bar (requires a water pressure regulator set to 3 bar).
  • Recommended CO₂ Pressure: 3 bar.
  • Recommended Inlet Water Temperature: 5-25 °C.
  • Working Room Temperatures: 2-32 °C.
  • Humidity: Keep unit away from humidity levels above 65%.
  • Electrical:
    • Compressor power: 110 W
    • Pump power: 10 W
    • Fan power: 16 W
    • Mixing motor: 25 W
    • Control power: 19 W
    • Heating element power: 500-800 W (model dependent)
    • UV Lamp: 13 W
    • Total max power (HCAS): 993 W
    • 24-hour standby power consumption: 0.46 kWh
    • Power supply: 220-240V/50Hz or 120V/60Hz
  • Refrigerant Gas: 230V/R600a or 120V/R134a. R600a (26g) and R134a (65g) are used, with R600a being a flammable gas available on 220/240V models only.
  • Connections: 1/4" CO₂ quick connect bulkhead, 1/4" Water quick connect bulkhead, drain plug for hot tank, drain plug for Ice Bath.
  • Certifications: ETL US Listed, BioCote, IAPMO R&T Water Quality Platinum Seal, UPC, Intertek, CE, BPA Free.
  • Clearance: Minimum 100 mm clearance around all surfaces for proper heat dissipation.

Usage Features:

  • User Interface: Features a large LCD screen with auxiliary messaging and an intuitive water dial for easy selection between five water types: Ambient, Sparkling, Cold, Hot, and Extra-Hot.
  • Dispense Status Bar: Indicates when water is being cooled and/or heated.
  • Bottles Saver Counter: A live indicator on the screen that monitors the number of 500ml plastic bottles saved during product use, promoting environmental awareness.
  • Ergonomic Dispensing Area: A generous 273 mm height allows for easy filling of sport bottles and other containers.
  • Child Safeguard: Prevents accidental dispensing of hot water.
  • High Capacity: Provides cold water for more than 50 users.
  • Eco-friendly Refrigeration: Uses R600a refrigerant gas (on 220/240V models) with low Global Warming Potential (GWP) and zero Ozone Depletion Potential (ODP).
  • Energy Saving Sleep Mode: Automatically turns off the heater after three hours of inactivity, reducing energy consumption.

Maintenance Features:

  • UV Lamp Change Interval: Recommended every 6 months, in line with NSF 55 Class A and P231 Certification requirements. Replacement must be performed by Waterlogic or authorized distributors with the power supply disconnected.
  • Leak Prevention System: Provides extra protection and reduces risks of accidents. Water block devices and external leak detectors are strongly recommended.
  • Installation and Service: Only qualified service technicians should attempt installation and service. The product must be completely drained and sealed before storage or transport to prevent stagnation and microbiological contamination.
  • Troubleshooting: The manual provides solutions for common errors such as UV Error, Hot Tank Heating Error, Sparkling Water Level Error, Ice Bath Level Error, Dispense Time Out, Hot Sensor Error, Ice Detection Error, and Ice Bath Circulation Error. Users are advised not to open panels, disconnect tubing, or touch electronic components, but to contact their Waterlogic supplier for repairs.
  • End of Life Disposal: For EU countries, the product is covered by the WEEE directive (2002/96/EC) and should not be disposed of with general household waste. For non-EU countries, disposal should be environmentally friendly and in line with local guidelines, with the supplier arranging collection and disposal.