WL290Manual Page57Revision9‐3‐2019
HOTWATERTROUBLESHOOTINGINDEX

1. HotWaterisnotHot85°C(185°+/‐5°F)

IncludedinthissectionaretheTwoResettableHotTankOverloads(HighLimitSafety)
Instructions.
1. HotWaterisnotHot85°C(185°+/‐5°F)
TheHottemperaturesetpointis85°C(185°F)andiscontrolledbyathermistorinthewellof
theHotTank.
TherearetwoHotTankOverloadDevices(HighSafetyLimit)onthesideoftheHotTankthat
willtriptopreventdamagetotheunitifthetankisdryheated(turnedonwithoutwaterin
it).
Ittypicallytakes10minutesforthe500Wtoheatthe1.6Literofroomtemperature
(ambient)watertothe85°C(185°F)setpoint.
PossibleReason Solution
Nopowertoheaterelements
CheckthattheRedHeaterandCompressor
switchison.
TurnRedHeaterandCompressorSwitchon.
I=ON
HotTankOverloadDevices
(HighSafetyLimit)tripped
HotTankOverloadDevices
(HighSafetyLimit)isasafety
featuretoensurethetankdoes
notoverheat.
HotTankOverloadDevices(HighSafetyLimit)will“click”
whenpushed.TheHotTankOverloadDevices(High
SafetyLimit)areautomaticallyresetwhenpressed.
SeeResetting HotTankOverloadDevices(HighSafety
Limit)Instructionsthatareincludedfurtherbelowinthis
TroubleshootingSection
HotTankOverloadDevices
(HighSafetyLimit)“open”on
HotTank
TurnPoweroff.
CheckOHM’sresistanceacrossterminalsoneachofthe
HotTankOverloadDevices(HighSafetyLimit)separately.
Goodcomponentswillindicateaclosedcircuitorzero
OHM’sonthemeter.
Replacecomponentsasnecessary.
Looseorimproperlyconnected
wire(s)totheheatingelement/
hottank.
Visuallyinspectwireleadsgongtothehottank;confirm
properconnectionstotheheatingelements.
Hottanklifeis3‐5years,dependingonusage.