Watlow 965 Series - Output 2 Wiring

Watlow 965 Series
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Install and Wire, Chapter 2
11
WATLOW Series 965 User's Manual
Output 2 Wiring
Solid-state Relay Without Contact Suppression, 0.5 Amp
Model # 965A - 3
K - 00 .
Switched DC Output
Model # 965A - 3
C - 00 .
Mechanical Relay Without Contact Suppression,
Form C, 5 Amp
Model # 965A - 3 D - 00 .
Figure 16 -
Switched dc Output
Wiring
External
Load
7
6
-
+
External
Load
7
6
NO
COM
1NC
Fuse
L1
L2
Customer Supplied
Quencharc
Figure 17 -
5 Amp Mechanical
Relay Wiring
Figure 18 -
0.5 Amp Solid-state
Relay Without
Contact Suppres-
sion Wiring
External
Load
7
SS2
SS2
1
Fuse
L1
L2
Custommer Supplied
Quencharc
Customer Supplied
Quencharc
NOTE:
Output is in open
State in Alarm
Condition.
NOTE:
Switching inductive
loads (relay coils,
solenoids, etc.) with
the mechanical
relay, switched dc or
solid-state relay
output options
requires using an
RC suppressor.
Watlow carries the
RC suppressor
Quencharc brand
name, which is a
trademark of ITW
Pakron. Watlow Part
No. 0804-0147-0000.
7
unregulated
V+
V—
6
Internal Circuitry
NOTE:
For more informa-
tion on alarms see
page 24.