A
Anthony MorrisAug 31, 2025
What does error code Er 10 mean on Watson Marlow Pumps 530 Water Pump?
- SSarah BruceAug 31, 2025
Error code Er 10 indicates a Tacho fault. Stop pump immediately and try to reset it by switching power off and on.
What does error code Er 10 mean on Watson Marlow Pumps 530 Water Pump?
Error code Er 10 indicates a Tacho fault. Stop pump immediately and try to reset it by switching power off and on.
What does error code Er 21 mean on Watson Marlow Pumps 530?
Error code Er 21 indicates an over signal. Reduce the analog control signal.
What does error code Er 20 mean on Watson Marlow Pumps 530?
Error code Er 20 indicates that the signal is out of range. Check the analog control signal range and trim the signal as required.
Why Watson Marlow Pumps 530 Water Pump turns on, but will not run?
If the pump turns on but won't run, check the remote stop function and its configuration. Also, verify the current mode; check if you are in analog mode. Try operating the pump in manual mode.
What does error code Er 14 mean on Watson Marlow Pumps 530?
Error code Er 14 indicates a speed error. Stop the pump immediately and try to reset the pump by switching the power off and on.
What does error code Er 15 mean on Watson Marlow Pumps 530?
Error code Er 15 indicates an over current issue. Stop the pump immediately and try to reset the pump by switching the power off and on.
What does error code Er 9 mean on Watson Marlow Pumps 530?
Error code Er 9 means the motor is stalled. Stop the pump immediately and inspect the pumphead and tube. Powering the pump off and on again may reset the system.
What does error code Er 17 mean on Watson Marlow Pumps 530?
Error code Er 17 indicates an under voltage issue. Stop the pump immediately and check the power supply. Powering the pump off and on again may reset it.
What does error code Er 16 mean on Watson Marlow Pumps 530 Water Pump?
Error code Er 16 indicates an over voltage issue. Stop the pump immediately and check the power supply. Powering the pump off and on again may reset it.
What to do if Watson Marlow Pumps 530 runs but there is little or no flow?
If the pump runs but there's little or no flow, first ensure that fluid is being supplied to the pump. Then, check for kinks or blockages in the lines and make sure any valves are open. Also, verify that the tube and rotor are properly installed in the pumphead, the tube isn't split or burst, the correct wall-thickness tube is being used, the direction of rotation is correct, and the rotor isn't slipping on the drive shaft.
Brand | Watson Marlow Pumps |
---|---|
Model | 530 Series |
Category | Water Pump |