DEMAND REGENERATION
You won’t have to worry about vacation settings or extra guests because the controller measures
water usage and regenerates based on need. The appliance will regenerate using only the necessary
amount of water and salt. If power has been turned off, your appliance will retain programmed
settings inde nitely.
1) ENTERING YOUR HARDNESS SETTING
See page 9 for determining your setting number. The water hardness setting number shown in the
digital readout will increase 1 grain each time you push the “SET” button. After 90 grains, the readout
will return to 1, and continue to count up from 1 until the display number matches the hardness
number. After 5 seconds the display will change to show “gallons remaining (x 100)”. To recheck the
hardness, touch “SET.”
2) GALLONS REMAINING
After setting water hardness, gallons remaining until the next automatic regeneration is shown in the
digital display. NOTE: Gallons remaining are in hundreds. 12=1,200 gallons.
3) RECHARGE/REGENERATION STATUS
Regeneration cycle numbers are shown during regeneration. The read-out will ash with the cycle
number. The ashing regeneration numbers are:
First cycle: (C1) First Backwash
Second & Third cycles: (C2) Brine/Slow Rinse
Fourth cycle: (C3) Second Backwash
Fifth cycle: (C4) Brine Re ll
Sixth cycle: (HO) Service
To quickly advance through the regeneration cycles, press and hold the REGENERATE button for 2
seconds.Wait for the cycle to begin, after 20 seconds press and hold the REGENERATE button
until the cycle number changes (about 2 seconds). Each cycle can be advanced in this manner.
4) waterMizer®
The waterMizer® wheel will turn whenever water is being used. See gure 10.
5) REGENERATE
To start an immediate regeneration, press The “REGENERATE” button and hold for 3 seconds. The
REGENERATE button is used when starting your water conditioner, to start an immediate regenera-
tion, or to restore capacity if you have run out of salt. If your appliance has run out of salt, you may
not have soft water available. Remove the salt lid and add salt. Wait two hours, then press the
“REGENERATE” button and hold for 3 seconds. See gure 10.