EasyManua.ls Logo

Watts AERCO Benchmark OMM-0136 - Page 67

Watts AERCO Benchmark OMM-0136
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Benchmark Platinum-Edge [II]: Operation-Service Manual
SECTION 5 SAFETY DEVICE TESTING
OMM-0137_E • GF-211 12/13/2019 Technical Support (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page 67 of 153
HIGH Gas Pressure Test Instructions: BMK3000 6000 ONLY
Figure 5-4c: High Gas Pressure Test Components BMK6000 shown
DOWNSTREAM
SSOV WITH POC
SWITCH
NATURAL GAS HIGH Gas
Pressure Port
Install manometer here for High
Gas Pressure test
PROPANE Gas Pressure Port
Install manometer here for High Gas Pressure test
Alternative location for manometer
if hose barb is preferred
PROPANE HIGH GAS
PRESSURE SWITCH
- BMK6000 10.5” W.C., 2.6 kPa
- BMK5000 4.5” W.C., 1.1 kPa
NATURAL GAS HIGH GAS
PRESSURE SWITCH
- BMK6000 10.5” W.C., 2.6 kPa
- BMK5000 11.0” W.C., 2.7 kPa
Alternative location
for manometer if hose
barb is preferred

Table of Contents