Watts AERCO Benchmark BMK5000 - User Manual

Watts AERCO Benchmark BMK5000
213 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Heating and Hot Water Solutions
AERCO International, Inc. • 100 Oritani Drive • Blauvelt, NY 10913
USA: T: (845) 580-8000 • Toll Free: (800) 526-0288 • AERCO.com
Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST
© 2020 AERCO
Other documents for this product include:
OMM-0144, GF-217 Installation and Startup Manual
OMM-0146, GF-219 Reference Manual
TAG-0019, GF-2070 Boiler Application Design Guide
TAG-0022, GF-2050 Vent-Combustion Air Design Guide
TAG-0047, GF-2030 Benchmark Gas Guide
TAG-0048, GF-2060 Benchmark Power Design Guide
Applies to serial numbers:
G-20-1800 and above BMK750 5000N
N-20-0125 and above BMK5000 & 6000
Operations and Service Manual
Benchmark
®
Boilers
with Edge
®
[i] Controller
Natural Gas, Propane Gas and Dual
Fuel Modulating & Condensing Boilers
Models 750 through 6000
OMM-0145_D GF-218 11/2/2020
Disclaimer
The information contained in this manual is subject to change without notice
from AERCO International, Inc. AERCO makes no warranty of any kind with
respect to this material, including, but not limited to, implied warranties of
merchantability and fitness for a particular application. AERCO International is
not liable for errors appearing in this manual, not for incidental or
consequential damages occurring in connection with the furnishing,
performance, or use of these materials.

Table of Contents

Other manuals for Watts AERCO Benchmark BMK5000

Questions and Answers

  • F
    floreschristineAug 7, 2025
    What to do if Watts AERCO Benchmark BMK5000 Boiler shows O2 Sensor Malfunction?
    • C
      Christina WangAug 8, 2025
      If your Watts Boiler displays 'O2 Sensor Malfunction', it could be due to a bad sensor, in which case you should replace it. Alternatively, there might be a communication issue; therefore, check the wires and connections.
  • J
    Jacqueline ColeAug 12, 2025
    What to do if Watts AERCO Benchmark BMK5000 Boiler displays O2 Sensor Out of Range?
    • G
      Glenda WalkerAug 12, 2025
      If your Watts Boiler shows 'O2 Sensor Out of Range', it could be because the sensor auto calibration offset required is more than ±3%. In this case, reset the unit and recalibrate the sensor. It could also be due to a bad sensor, which would require replacement, or, rarely, a bad ECU, which should also be replaced.
  • B
    Barbara HardyAug 16, 2025
    Why is the O2 percentage low in my Watts AERCO Benchmark BMK5000?
    • K
      Kathy AvilaAug 16, 2025
      If the O2 percentage is low in your Watts Boiler, it could be caused by a dirty filter or poor combustion calibration. If this is the case, recalibrate the unit. It could also be due to an O2 Offset that is too low, in which case you should increase the O2 Offset value. Finally, a bad sensor could be the culprit, requiring replacement.
  • R
    Robin BrownAug 21, 2025
    What to do if Watts AERCO Benchmark BMK5000 displays Warning O2 Level High?
    • T
      Thomas MillerAug 21, 2025
      If your Watts Boiler is showing a 'Warning O2 Level High' message, this could be due to a Gas Pressure Regulator or Air Blower problem, or bad Combustion Calibration. A high O Offset could also be the cause. In some cases, a bad sensor may be the problem and should be replaced.
  • L
    Lindsey NguyenAug 25, 2025
    What causes the O2 Warning Service Required on a Watts AERCO Benchmark BMK5000 Boiler?
    • C
      Christina GriffithAug 25, 2025
      If the Watts Boiler displays 'O2 Warning Service Required', the issue might stem from the gas supply, air filter, or air blower. Alternatively, a bad sensor could be the cause and require replacement.
  • S
    Stephanie FarrellAug 29, 2025
    How to fix BV Hi Err on Watts Boiler?
    • T
      Timothy WigginsAug 29, 2025
      If your Watts Boiler displays 'BV Hi Err', check the air filter, gas regulator, and combustion calibration.
  • C
    Caitlin WardSep 2, 2025
    How to resolve Max Iter error on Watts Boiler?
    • N
      Nicole HowellSep 2, 2025
      If your Watts Boiler is displaying 'Max Iter', check the sensor calibration for inaccuracies. You can also try to increase the gain or iteration attempts.

Watts AERCO Benchmark BMK5000 Specifications

General IconGeneral
BrandWatts
ModelAERCO Benchmark BMK5000
CategoryBoiler
LanguageEnglish