Watts BT-DRF-02 - Floor Temperature and Regulation Settings; Concrete and Floor Covering Choices

Watts BT-DRF-02
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
22
View of the measured values of the
internal sensor.
“__._”
23
View of the measured values of the
external (Ambient) sensor.
“__._”
24
View of the measured values of the floor
sensor connected to the receiver.
“__._”
25
FL.L
Lower limit of the floor temperature.
“no”
The lower limitation is
not used
From 5°C to “FL.Hi”
26
FL.H
Upper limit of the floor temperature.
“no”
The upper limitation is
not used
From “FL.Lo” to 40°C
27
tYP
Selection of regulation type.
“bp”
Proportional band
(PWM)
“hys”
Hysteresis (On/Off)
28
UF1
Concrete choice.
“uf1”
For liquid concrete
with low thickness
< 6cm
“uf2”
For traditional
concrete with
thickness
> 6cm