EasyManua.ls Logo

Wavetek 132 - Section 2 Operation - Power Conversion; Converting to 230-Volt Line Power

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Converting
to
230-Volt Line Power
Instruments are
shipped
from the factory
with the
power
transformer connected
for 115-volt line
power,
unless ordered for 230-volt use.
Converting
a
115-volt
unit
for
230-volt
operation is
a
simple
matter.
1.
Remove
power cord.
2.
Loosen two captive thumb screws on rear panel
and remove
panel.
3. The conversion switch is located on
the chassis.
Use a thin-bladed
screwdriver to move the
115-
230
switch
to the
230
position.
4. Replace 1/4-ampere fuse with
a
1/8-ampere
fuse
of
the same type.
10