OWNER’S MANUAL
A MAJOR CAUSE OF FIRES IS FAILURE TO
MAINTAIN REQUIRED CLEARANCES (AIR SPACES)
TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST
IMPORTANCE THAT THIS PRODUCT BE INSTALLED ONLY
IN ACCORDANCE WITH THESE INSTRUCTIONS.
Wood Pellet Grill
51779
US
01/14/20

Other manuals for Weber SMOKEFIRE EX6

Questions and Answers

  • R
    Rita CampbellAug 20, 2025
    What to do if my Weber SMOKEFIRE EX6 is too hot?
    • M
      Margaret ThompsonAug 20, 2025
      If your Weber Grill is overheating, follow these steps: 1. Allow the barbecue to complete the shutdown procedure and cool down completely. Keep the lid closed and do not unplug or power it off during this process. 2. Once cool, power off the grill and unplug it. 3. Open the lid and remove the cooking grates, FLAVORIZER BARS, heat diffuser, and heat baffle. 4. Clean the cookbox and burn pot of ash and debris, directing it into the ash and grease system. Ensure the ash is fully extinguished before cleaning. 5. Reinstall the heat baffle, heat diffuser, FLAVOURISER bars, and cooking grates. 6. Clean the ash and grease system, reinstall the drawer, and replace drip pans if needed. 7. Plug the grill back in and power it on.
  • J
    James RhodesAug 25, 2025
    What to do if my Weber SMOKEFIRE EX6 displays E1 error?
    • K
      Kimberly PinedaAug 25, 2025
      If your Weber Grill displays an E1 error, it indicates an auger jam. The grill will attempt to clear the jam automatically. If the grill is still hot, it will run the shutdown procedure, so open the lid and wait until it has cooled completely. Do not unplug the grill during this process. Once cooled, power off the grill and unplug it. Remove the cooking grates, FLAVORIZER bars, heat diffuser, and heat baffle. Clean the cookbox and burn pot of any ash or debris. Reinstall the heat baffle, heat diffuser, FLAVORIZER bars, and cooking grates. Clean the ash and grease system, reinstall the drawer, and replace grease drip pans if needed. Finally, plug the grill back in and power it on.
  • J
    Joshua AndersonAug 26, 2025
    What does E3 error mean on my Weber SMOKEFIRE EX6 Grill and how to fix it?
    • J
      Jonathan ParksAug 27, 2025
      An E3 error on your Weber Grill indicates that the grill flame is out. The grill will automatically start the shutdown procedure if it's still hot, so open the lid and allow it to cool completely without unplugging it. Once the shutdown is complete, power off the grill and unplug it from the power source. Remove the cooking grates, FLAVORIZER bars, heat diffuser, and heat baffle from the cookbox. Clean any ash or debris from the cookbox and burn pot. Then, reinstall the heat baffle, heat diffuser, FLAVORIZER bars, and cooking grates. Clean the ash and grease system, reinstall the drawer, and replace the grease drip pans as needed. Finally, plug the grill back into the power source and power it on to begin cooking.
  • G
    Gabriel CarrollAug 30, 2025
    What does E4 error mean on my Weber SMOKEFIRE EX6?
    • M
      Madison NguyenAug 30, 2025
      The E4 error code on your Weber Grill indicates a communication failure. If the grill is still hot, it will automatically run the shutdown procedure. Open the grill lid and wait until the grill has completed the shutdown procedure and completely cooled. Do not unplug the grill during this process. Once the shutdown procedure is complete, power off the grill and unplug it from the power source. Wait one minute, then plug the grill back in and power it on to begin your cook.
  • G
    George VelezSep 3, 2025
    What does E7 error mean on my Weber SMOKEFIRE EX6 Grill?
    • K
      Kimberly BeltranSep 3, 2025
      The E7 error on your Weber Grill indicates a motor failure. If the grill is still hot, it will automatically run the shutdown procedure. Open the grill lid and wait until the grill has completed the shutdown procedure and completely cooled. Do not unplug the grill during this process.
  • R
    Rebecca WilliamsSep 5, 2025
    What does E9 error mean on my Weber SMOKEFIRE EX6 Grill?
    • V
      Victoria WheelerSep 5, 2025
      The E9 error on your Weber Grill indicates a low fuel detection error. If the grill is still hot, it will automatically run the shutdown procedure. Open the grill lid and wait until the grill has completed the shutdown procedure and completely cooled. Do not unplug the grill during this process.
  • J
    Jose PhillipsSep 7, 2025
    What does E8 error mean on my Weber Grill?
    • C
      Cory WiseSep 7, 2025
      The E8 error code on your Weber Grill indicates a thermocouple error. If the grill is still hot, it will automatically run the shutdown procedure. Open the grill lid and wait until the grill has completed the shutdown procedure and completely cooled. Do not unplug the grill during this process.
  • M
    Michael LopezSep 9, 2025
    What to do if my Weber SMOKEFIRE EX6 Grill shows E1 error?
    • M
      Melissa KingSep 9, 2025
      An E1 error on your Weber Grill indicates an auger jam. The grill will attempt to clear it automatically. If that doesn't work: 1. Allow the barbecue to complete the shutdown procedure and cool down completely. Do not unplug or power it off during this process. 2. Once cool, power off the grill and unplug it. 3. Remove the cooking grates, FLAVORIZER BARS, heat diffuser, and heat baffle. 4. Clean the cookbox and burn pot of ash and debris, directing it into the ash and grease system. Ensure the ash is fully extinguished before cleaning. 5. Reinstall the heat baffle, heat diffuser, FLAVORIZER bars, and cooking grates. 6. Clean the ash and grease system, reinstall the drawer, and replace drip pans if needed. 7. Plug the grill back in and power it on.
  • Q
    qmannSep 12, 2025
    What to do if my Weber Grill shows E4 communication failure error?
    • W
      William DelgadoSep 12, 2025
      If your Weber Grill displays an E4 error, which indicates a communication failure, here’s what to do: 1. Allow the barbecue to complete the shutdown procedure and cool down completely. Do not unplug or power it off during this process. 2. Once the shutdown procedure is complete, power off the barbecue and unplug it from the power source. 3. Wait one minute, then plug the barbecue back into the power source and power on the barbecue to begin your cooking session.
  • C
    christopher92Sep 13, 2025
    What does E9 mean on my Weber SMOKEFIRE EX6 Grill?
    • J
      Julie MortonSep 13, 2025
      An E9 error code on your Weber Grill indicates a low fuel detection error. The barbecue will automatically run the shutdown procedure if the barbecue is still hot. Open the barbecue lid and wait until the barbecue has completed the shutdown procedure and completely cooled. Do not unplug the barbecue or power it off during the shutdown procedure.

Summary

Safety

General Safety Warnings

Lists critical safety precautions for grill usage and environment.

Dangers of Indoor and Enclosed Use

Highlights critical dangers like indoor use, confined spaces, and commercial use.

Safety (Continued)

Additional Safety Precautions

More warnings regarding water, liquids, extension cords, probes, and hopper.

Cooking System Components

Special Features Overview

WEBER CONNECT Controller Functions

Using Controller Functions

Guides on using selection dial, cook programs, and timers.

Before Igniting Your Grill

Choosing a Proper Cooking Location

Provides essential guidelines for selecting a safe outdoor location for the grill.

First-Time Startup Preparation

Outlines initial setup steps before the first use of the grill.

Before Igniting (Continued)

Grill Operation Procedures

First Time Grill Startup Procedure

Detailed steps for the initial setup and seasoning of the grill.

Every Time You Cook Startup

Routine steps to follow for preheating and starting each cooking session.

Grill Operation (Continued)

Using Food Temperature Probes

Instructions on how to use food temperature probes for monitoring.

Proper Grill Shutdown Procedure

Steps for safely powering down the grill after cooking.

Controller Settings

Probed Cooking Setup

Guides on configuring the grill for cooking with temperature probes and settings.

Controller Settings (Continued)

Using Guided Cook Programs

Instructions for using guided cook programs.

Troubleshooting

E1 Error: Auger Jam

Details the cause and solution for the auger jam error.

E2 Error: Fan Malfunction

Explains the cause and solution for a fan malfunction error.

E3 Error: Grill Flame Out

Describes how to resolve an error where the grill flame is extinguished.

Troubleshooting (Continued)

E4 Error: Communication Failure

Addresses issues related to communication errors between components.

E7 Error: Motor Failure

Explains how to diagnose and fix motor failure errors.

E5 Error: Grill Overheating

Provides solutions for when the grill temperature is excessively high.

E8 Error: Thermocouple Error

Provides solutions for errors related to the thermocouple.

E6 Error: Startup Failure

Details troubleshooting steps for errors during grill startup.

Maintenance Procedures

Weber SMOKEFIRE EX6 Specifications

General IconGeneral
Grill TypePellet Grill
Total Cooking Area1008 sq in
Temperature Range200°F to 600°F
Fuel TypeWood Pellets