38 of 68
TECHNICIANS manual
Problem Cause Action
GROUNDS IN CUP
tī The īlter holder is dirty.
tī The īlter holes are worn.
tī The coīee is not ground evenly.
tī The seal under the pad is worn
tī The pressure in the pump is too high.
tī Clean the īlter holder.
tī Replace the īlter.
tī Replace the grinders.
tī Replace the seal.
tī Adjust the pressure of the pump
THE CUP IS DIRTY WITH SPLASHED
COFFEE
tī Steam pockets in the dispensing system.
tī Air pockets in the hydraulic circuit.
tī Coīee is ground too coarsely
tī Reduce the water temperature.
tī Check the cause and eliminate the problem.
tī Adjust the grinding suitably.
COFFEE IS TOO COLD
tī The electrical heating element of the coīee boiler
is faulty.
tī The wiring is faulty.
tī Lime scale on the exchangers and/or heating ele-
ment.
tī The pressure switch contacts are oxidized.
tī The heating element protection thermostat inter-
vened.
tī Machine switch in ā1ā position
tī Lime scale has reduced the circulation of water.
tī The dispensing group is cold.
tī Replace the boiler's electrical heating element.
tī Check for any faulty connections.
tī Clean the machine.
tī Clean the contacts or replace the pressure switch.
tī Reset the heating element protection.
tī Place the machine switch in the "2" position
tī Clean the connections of the exchanger, and clean
or replace the two circulation tubes
tī Eliminate air pockets in the hydraulic circuit in the
following manner:
- disconnect the pump from the power supply;
- close the water tap of the softener;
- perform a dry dispensing run for a few minutes;
- connect the pump to the power supply;
- open the water outlet tap of the softener;
- dispense until water comes out;
- wait a few minutes for heating.
COFFEE IS TOO HOT
tī Boiler temperature is too high.
tī The īow reducer of the group is not suitable
tī
Reduce the pressure in the boiler using the appropri-
ate screw on the pressure switch.
tī Replace the reducer with one of a smaller diameter.
COFFEE IS BEING DISPENSED TOO
QUICKLY
tī Coīee is ground too coarsely
tī The diameter of the injector is too large.
tī The dose of ground coīee is too small.
tī Adjust the grinding of the coīee.
tī Replace the injector with one of a smaller diameter.
tī Check the amount (grams) of the ground coīee you
are using.
COFFEE IS BEING DISPENSED TOO SLOWLY
tī Coīee is ground too īnely.
tī The injector is clogged.
tī The dispensing group is clogged.
tī The īlter holder is dirty.
tī Adjust the grinding of the coīee.
tī Replace the injector.
tī Check and clean the dispensing group.
tī Clean and replace the īlters, if necessary.
EVD version:
SHUTDOWN OF THE ELECTRONIC SYSTEM
tī The control unit fuse is burned out.
tī One of the volumetric dispenser's contacts is
grounded.
tī Replace the main fuse (125 mA).
tī Check the connection of the volumetric dispenser.
EVD version:
COFFEE DISPENSING OCCURS ONLY USING
THE MANUAL BUTTON
tī The control unit fuse is burned out.
tī The coil of the solenoid valve does not work correctly
or has shorted out.
tī Replace the control unit fuse (1A).
tī Replace the coil of the solenoid valve.
EVD version:
SHUTDOWN OF THE ELECTRONIC SYSTEM
tī The control unit fuse is burned out.
tī One of the volumetric dispenser's contacts is
grounded.
tī Replace the main fuse (125 mA).
tī Check the connection of the volumetric dispenser.