Engine Hoist
While lifting, the centerline of the crankshaft of the engine must be kept level; no tilt or single-
point lifting. Lift and lower slowly (See Illustration 1)
Illustration 2- Engine Installation Diagram
Extreme Operating Conditions
1. Engine Speed
This engine is designed to operate at constant speed (1000 to 2200 RPM) and should not
exceed 2400 RPM for any length of time. If engine is operated at excessive RPM, fuel and
ignition systems will shut down until engine RPM decreases to the recommended operating
RPMs.
2. Over Temperature
CAUTION
To prevent engine damage, shut down engine immediately if the coolant reaches operating
temperature above 230°F (110°C).
Normal operating temperature for this engine is 180°F to 203°F (82°C to 95°C).