6.4.1 Menu structure end user level
Menu points and parameters are hidden or displayed according to the settings made
in the heating engineer level and according to the module used for the system (e.g.
several heating circuits).
Menu point
Parameters Description Factory pre-
setting
Set
Info 01 External min
02 External max
03 Yield counter
04 Total yield
05 Statistic
Remote control P101 Room sensor corr 0.0K
P102 Contrast 04
P103 Illumination 30
Settings#1 P111 Type of operation HC
P112 Normal room temp 21.5°C
P113 Setback room temp 16.0°C
P114 Acceptance room Off
P115 Normal supply setpoint 75.0°
C75.0°C
P116 Setback supply setpoint 45.0°C
P117 Gradient 10.0
P118 Room frost temp 10.0°C
P119 Su/Wi change 20.0°C
Settings#2 P121 Normal supply set-
point#2
75.0°C
P122 Setback supply set-
point#2
45.0°C
P123 Gradient
P124 Su/Wi change 20.0°C
DHW P132 Normal DHW setpoint 50.0°C
P133 Setback DHW setpoint 40.0°C
P134 Acceptance DHW Off
Holiday P141 Duration
P142 Temp level Frost
Time-Date P151 Date
P152 Time
P153 Summertime start 25.March
P154 Summertime end 25.Oct
Time program Heating program 1
Heating program 2
Heating program 3
P161 Advance #2 10 min
DHW program
Circ. program
Installation and operating instruction
Remote control station WCM-FS 2.0 and extension module WCM-EM 2.1
6 Operation
83277502 • 3/2012-10 • La
30-106

Table of Contents

Other manuals for Weishaupt WCM-FS 2.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Weishaupt WCM-FS 2.0 and is the answer not in the manual?

Weishaupt WCM-FS 2.0 Specifications

General IconGeneral
BrandWeishaupt
ModelWCM-FS 2.0
CategoryControl Systems
LanguageEnglish

Related product manuals