Part Number STH098 06/19 29
,
Caution
Do not mix Ice Machine Cleaner/Descaler and Sanitizer
solutions together. It is a violation of Federal law to use
these solutions in a manner inconsistent with their
labeling.
Step 3 To start a descaling cycle, select Clean. Water
will flow through the water dump valve and down the
drain. Wait until the water trough refills, then add the
proper amount of ice machine cleaner/descaler to the
water trough.
Model Amount of Cleaner/Descaler
Part Number 9405463
UDP0140 2 ounces (60 ml)
UDP0240 5 ounces (150 ml)
UDP0310 5 ounces (150 ml)
Wait until the cycle is complete (approximately 22
minutes) then press the On/Off button and disconnect
power and water supplies to the ice machine.
Step 4 Remove parts for descaling.
Refer to the proper parts removal for your machine.
Continue with step 5 when the parts have been removed.