Welch Allyn MicroTymp® 4 Tympanometer
User Manual
DIR 80024157 Ver A Page 13
selected levels. Press the key to confirm the selection or the key to cancel. (Note that
100dBHL at 4000Hz is not available).
REFLEX POLARITY
Use the and keys to choose whether the reflex traces are displayed as ascending (UP) or
descending (DOWN). Press the key to confirm the selection or the key to cancel.
REFLEX FILTER
Use the keys to choose either 2Hz or 1.5Hz. The default of 2Hz is suitable for most circumstances.
However, if a smoother reflex plot is required for better interpretation 1.5Hz may be chosen.
Press the key to confirm the selection or the key to cancel.
SET TIME/DATE
Use the keys to enter the values for the date and time. Use the and keys to change the
values. Press the key to confirm and save the selection or the key to cancel.
POWER OFF DELAY
The Welch Allyn MicroTymp 4 will switch off automatically if no key is pressed for a specified
duration. Use the and keys to change this duration between 90 and 180 seconds and press
the key to confirm and save the selection or the key to cancel.
LCD CONTRAST
Use the and keys to change the contrast of the LCD screen; press the key to confirm and
save the selection or the key to cancel.
REPORT CAL DATE
The printout of the test results may include date of the instrument’s calibration. Use the and
keys to select if the calibration date is printed or hidden. Press the key to confirm and save
the selection or the key to cancel.
SET DATE FORMAT
The Welch Allyn MicroTymp 4 supports two different date formats. Use the and keys to
select either DD/MM/YY or MM/DD/YY and press the key to confirm and save the selection or
the key to cancel.
HOSPITAL NAME
The printout of the test results may include the hospital name (up to 19 characters). To enter
the hospital name use the and and and keys to select the letter then press and briefly
hold the key to confirm. To delete the last letter briefly hold the key. Once the name has
been entered highlight the # key then press and briefly hold the key to save the name.
Highlight the # key then press and briefly hold the key to cancel.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Welch Allyn MICROTYMP 4 and is the answer not in the manual?

Welch Allyn MICROTYMP 4 Specifications

General IconGeneral
BrandWelch Allyn
ModelMICROTYMP 4
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals