FINAL INSPECTION
Verify the following:
1. There are no leaks or loose components.
2. The hot water is over 160°F.
3. The cold water is below 50°F.
4. Confirm acceptable product water flow
5. Wellsys W9 RO system should fill at a rate of about 5.1 L/min.
a.
Note:
Incoming water pressure and drain correctly functioning will
have a significant impact on water flow. The flow will also
improve as the membrane breaks in.
6. Wellsys W9 UF system should fill in about 5-10 min
7. If the system is not filling, then check the water supply and also make
sure you did not trip the leak stop.
a. The leak stop can be reset by removing the cap below the unit
and draining the water out.
8. Ensure the system’s exterior is clean and all components are in place.
Other Items:
1. Once a system has been flushed it should remain plugged in and water
should at a minimum be dispensed occasionally.
a. Avoid storing in your vehicle or warehouse with residual water in
the tank, this will result in a bad taste after installation.
2. Always drain the system before moving it. It is not necessary to drain
the Hot Tank completely through the rear Hot Tank drain if installing
same day. Leaving water in the Hot Tan will allow turning on the Hot
Tank immediately after installation of the system but if left overnight
may result in a taste complaint that could even impact the cold tank.
3. Never lay the system on its side.